Home > General Electric (GE)

General Electric (GE) Interlock Kits

We’re proud to say that our General Electric Interlock Kits are made here in the USA, and each Kit is custom designed to work with the GE electrical panel on your home. Each Kit acts like a manual transfer switch, allowing you to safely and easily connect your generator to your panel. The difference? Our Kits are easier to install than traditional manual transfer switches. As a result, you’ll pay less for the professional installation that we recommend.

Need assistance figuring out the right General Electric Kit for your home? Call us and we’ll be happy to help!

Sort By:
Page of 1
General Electric Kit K-8010 Kit K-8015
This Kit mounts to Siemens, GE, Square D, Cutler Hammer, Thomas & Betts, Challenger, Crouse-Hinds, and Westinghouse electrical panels; requires:

  • Horizontal (left-right) throw
  • Two two-pole breakers
  • Works in all four corners
Main: two-pole; generator: two-pole. Fits any feed-through panel with two double-pole 1" breakers.

Kit Installation Instructions
This Interlock Kit performs like a manual transfer switch for General Electric (GE) electrical panels and requires:

  • Horizontal (left-right) throw
  • Four-handle breaker
  • Offset 5/8" right of center of the two breaker columns
  • Distance from columns: 1¼" (above)
Space between breaker columns: ½"; two panel spaces required for this Kit.

Kit Installation Instructions
This Interlock Kit mounts to General Electric (GE) electrical panels and requires:

  • Horizontal (left-right) throw
  • Two-pole handle breaker
  • Offset 5/8" right of center of the two breaker columns
  • Distance from columns: 1¼" (above)
  • Space between breaker columns: ½"; two panel spaces required for this Kit.

    Kit Installation Instructions
Kit K-8110 Kit K-8210 Kit K-8310
This Kit mounts to General Electric (GE) electrical panels with the following features:

  • Vertical (up-down) throw
  • One-handle breaker
  • Centered over columns
  • Distance from columns: 2½" (above)
Space between breaker columns: ½"; three panel spaces required for this Kit.
Kit Installation Instructions
This Interlock Kit mounts to General Electric (GE) electrical panels and requires:

  • Vertical (up-down) throw
  • Four-handle breaker
  • Centered under columns
  • Distance from columns: 2½" (below)
This Interlock Kit mounts to General Electric (GE) electrical panels and requires:

  • Vertical (up-down) throw
  • Four-handle breaker
  • Centered over columns
  • Distance from columns: 2¼ to 2½" (above)
Space between breaker columns: ½"; two panel spaces required for this Kit.

Kit Installation Instructions
This Kit mounts to GE electrical panels and requires:

  • 8 blank panel, 1" breakers
  • Horizontal (left-right) throw
  • Two-handle breaker
  • Distance from columns: 0" (above)
  • Sits on top of either column
Space between breaker columns: ½"; two panel spaces required for this Kit.

Kit Installation Instructions
This Kit mounts to General Electric electrical panels with the following features:

  • 12 blank panel, 1" breakers
  • Horizontal (left-right) throw
  • Two-handle breaker
  • Distance from columns: 0" (above)
  • Sits on top of either column
Space between breaker columns: ½"; two panel spaces required for this Kit.

Kit Installation Instructions
This Kit mounts to GE electrical panels with the following features:

  • Vertical (up-down) throws
  • Four-handle breaker
  • Sits parallel to column below
Space between breaker columns: 2-5/8"; two panel spaces required for this Kit.